We are having Unique and Comprehensive Calibration Service Facilities for Primary in-house facility for force calibration. We have state of art in-house/onsite calibration facility in Vadodara for Force, Temperature and Pressure Parameter. We have complete set of equipments, knowledge & skills to provide laboratory as well as onsite calibration facility.

We proud to say that Hemshell Services is a Sole Calibration Laboratory in India which is using the imported Gold Standard Interface, Ametek-Jofra makes Reference standards. Reference Standard from Hemshell are calibrated from the NPL and International Laboratory Accreditation Cooperation (ILAC) laboratory.

Our standards have traceability to national / international standards, and calibrated from NPL and Ametek Calibration Instruments traceable to the ILAC & DANAK in Denmark through recognized international laboratories. So the customers can be assured as to the accuracy of their instrument. Calibration, which is a process of comparison, is therefore associated with a level of uncertainty. Our reports indicate the uncertainty associated with the measurements. Our team works, keeping the ‘Clients requirements’ as the focus.

Measurement:

Dead Weight Machine

  • High Accurate as per IS 4169:2014
  • Capability: – 50N to 5000N for tension and compression.
  • RS232 communication, special calibration and data storage software are included

Interface Gold Standard Load Cell with Digital Display

  • High Accuracy : Class 0
  • Capability : 10N to 300kN for tension and compression by using changeable load cells.

Reference Digital Temperature Indicator with Reference Sensor DTI-1000 & STS 100

  • High Accuracy : DTI-1000: ±0.005°C & DTI-1000 + STS probe: ±0.03°C ± LSD
  • Wide Temperature Range : DTI-1000: -200 to 750°C & STS-100 probe:-150 to 650°C
  • Resolution : 0.1°/ 0.01°/ 0.001ºC
  • Reliable temperature readings : The measuring principle is a 4-wire True Ohm Measurement, which eliminates the EMF in cables, sockets, and sensors
  • Dual channel : RS232 communication, special calibration and data storage software are included

Reference Temperature Calibrator RTC-700

  • High Accuracy : ±0.11°C using the external reference sensor. 4-wire True-Ohm-Measurement technology is used.
  • Excellent Stability : ± 0.008˚C to 0.02˚C
  • Wide Temperature Range : 33 to 700ºC
  • Resolution : 1°, 0.1°, 0.01° or 0.001ºC
  • Improved Temperature Homogeneity : Unique active triple-zone block ensures good temperature homogeneity in the calibration zone.
  • DLC Dynamic Load Compensation
  • Display Indicator For Temperature Uniformity
  • Large Easy-To-Read Colour VGA Display With Perfect

Measurement:

Reference Temperature Calibrator RTC-700

  • High Accuracy : ±0.11°C using the external reference sensor. 4-wire True-Ohm-Measurement technology is used.
  • Excellent Stability : ± 0.008˚C to 0.02˚C
  • Wide Temperature Range : 33 to 700ºC
  • Resolution : 1°, 0.1°, 0.01° or 0.001ºC
  • Improved Temperature Homogeneity : Unique active triple-zone block ensures good temperature homogeneity in the calibration zone.
  • DLC Dynamic Load Compensation
  • Display Indicator For Temperature Uniformity
  • Large Easy-To-Read Colour VGA Display With Perfect

Overview Of The Actual status

  • Calibration Software Included
  • Having Input facility for reference sensors, DLC Sensor, RTD & All type of Thermocouples, Temperature Switch, Transmitter, Voltage
Reference Temperature Calibrator RTC-158 (Use as a Liquid Bath as well as Dry Block Bath)
  • High Accuracy : ±0.04°C using the external reference sensor. 4-wire True-Ohm-Measurement technology is used.
  • Excellent Stability : ± 0.01˚C
  • Wide Temperature Range : -22 to 155ºC
  • Resolution : 1°, 0.1°, 0.01° or 0.001ºC
  • Dual Functions : Use as a Liquid Bath as well as Dry Block Bath                                                                                                                                                                                           
  • Excellent Temperature Homogeneity: Unique active dual-zone block ensures good temperature homogeneity in the calibration zone.
  • DLC Dynamic Load Compensation
  • Display Indicator For Temperature Uniformity
  • Large Easy-To-Read Colour VGA Display With Perfect Overview Of The Actual status
  • Calibration Software Included
  • Having Input facility for reference sensors, DLC Sensor, RTD & All type of Thermocouples, Temperature Switch, Transmitter, Voltage

Pressure Measurement:

Pneumatic Deadweight Tester RK-20B-1A/C

  • Pressure Range : 0.01 to 20 bar
  • Accuracy : ±0.015% of Indicated reading
  • Repeatability : ±0.005% of indicated reading
  • Special Calibrations/Local Gravity : RK testers are supplied standard with masses calibrated to International Standard gravity of 9.80665 m/s2. Local gravity calibration is available on this model
  • Exceptional Performance and Safety Built-In : Floating Ball Operation
    • Self-Regulating
    • Rugged Ceramic Measuring Ball
    • Overhung Weight Carrier
    • Non-Contaminating Test Fluid
    • Closed Cover Operation
    • Interchangeable Weights
    • Ball Valves for Inlet and Outlet
    • NIST Traceable

Pneumatic Deadweight Tester RK-20B-1A/C

  • Wide Pressure Range : 16 pressure ranges, ranging from -1 to 700 bar F.S. Absolute, differential and gauge sensors.
  • Accuracy : ±0.025% of reading +0.01% F.S
  • True field calibrator : Fully temperature compensated
  • Single or dual sensor versions: Eliminate the need for 2 separate calibrators.
  • Full set of intelligent features: Wide selection of useful functions and features. Damping, leak test, % error calculation, min/max, switch test, etc.
  • Another Functions : It can be also measure RTD, mA (Transmitter) ,Voltage, Switch Test
  • It can be extended with many different pressure modules, with accuracy up to 0.01% F.S

Advance Pressure Module APM-700G

  • Wide Pressure Range : 25mbar to 700 bar F.S. Absolute, differential and gauge sensors.
  • Accuracy : ±0.025% of reading +0.01% F.S
  • Rugged construction : Cast aluminium housing. Engineered for rough field use, almost unbreakable
  • Self contained intelligent module: : Calibration data are stored and processed inside the APM. Enabling use of the APM with any JOFRA calibrator, without initial calibration of the “system”. Calibration and traceability follows the module!

Pneumatic Pressure Pump T-975

  • Pressure Range : -0.91 to 40 bar
  • Bi-directional Pump system
  • Convenient and Easy to Use

Pneumatic Pressure Pump T-975

  • Pressure Range : 0 to 1000 bar
  • Hydraulic Oil or Water Pump system
  • More than 1.2 litre Liquid Reservoir
  • Convenient and Easy to Use
  • Hand pump mounted on drip pan with manifold pipe assembly: (one each) ¼” & ½” pipe thread union bodies: and (one each) 5/8” x ¾”, 1” & 1 1/8″ wrenches.

RockwellCum Superficial Hardness tester

  • Calibration Done as per IS 1586 : 2000
  • Capability :HRC & HR 15N scale in Direct/ Indirect calibration Method
  • Using Highly Accurate Imported Hardness Block as Master – Make of Newage – YAMAMOTO.
  • Tolerance with in ± 0.5 HRC.

  •  Master Block Traceable to NIST.